After years of successful reliable applications, a componentfailure on a new application cannot be explained with static stressanalyses, modal failure analysesmay be required. Finite elementmodal analyseswas used to identify the mode and its frequency thatcause a high range gear and drive ring assembly to failprematurely. ACampbellDiagram was used to identifymodes in theoperating range of a six–speed transmission that could cause thedrive ring to fail. Redesigning the assembly to move thecriticalmodes out of the operating range is described.