A trial test of the calibration procedures outlined in ISO18653, Gears- Evaluation of instruments for the measurement ofindividual gears, showed that the results are reasonable, but aminor change to the uncertainty formula is recommended. Gearmeasuring machine calibration methods are reviewed. The benefitsfrom using work-piece like artifacts are discussed and a procedurefor implementing the standard in the work place is presented.Problems with applying the standard to large gear measuringmachines are considered and some recommendations are offered.
- Edition:
- 09
- Published:
- 09/01/2009
- Number of Pages:
- 15
- File Size:
- 1 file , 520 KB