A process validation protocol for demonstrating the effectiveness and reproducibility of sterilizing vial stoppers and aseptic filling components used in the aspetic filling of Biotin.Sterilization process incorporates Mueller autoclave, model SS-244 .Acceptance criteria includes Thermocouple values, 12-log reduction of bioburden values, non-growth of biological indicators, and review of procedures pertaining to the monitoring, maintenance and operation of the system.Attached forms include a Sterilization Cycle Summary and Thermocouple & Biological lndicator Placement Diagram.Adheres to PDA Technical Monograph No. 1, “Validation of Steam Sterilization Cycles,” and USP XXII.The PV Report is available as 02-0043-PVR-1.0.