This test procedure determines the expected wear-out lifetimefor aluminum electrolytic capacitors. It provides a measure of theoperating time required for parametric changes to cause capacitorsto become unusable as filter capacitors on rectified mainsapplications. While it measures the time till wear-out, it does notindicate failure rate during the operating life. Wear-out isdefined by conditions specified in table 1. Measurements are to betaken periodically and the measurements are to be taken at the sametemperature throughout the test.